Structural functional features
-
Oven in which the air heated by the heater located on the inner bottom side is naturally air flows on the inside.
-
Easy to open and close the door. Soft handle minimizes shock to the sample.
-
Includes vent hole base with cover for gas exhaust.
-
Excellent visibility and viewing angle due to application of 4.7-inch large VFD.
Use Convenience Feature
-
3-point temperature calibration, high temperature accuracy over a wide temperature range.
-
Optimized control with temperature auto-tuning.
-
Save and use 3 frequently used temperatures.
-
Wait On/Off timer. (up to 999 hours 59 minutes)
-
Microprocessor PID method for precise temperature control.
-
Monitor via mobile app anytime, anywhere with LC Connected mobile monitoring system
(when purchased LC GreenBox)
-
Automatic restart of operation when power is restored after sudden power failure.
Outstanding Safety
-
Top-rated overheating protection system. (Registration 10-0397583)
-
Over temperature limit function. (Over Temperature Limiter)
-
Safe product surface, even when operated at upper temperature.
-
Triple-toughened viewing window for safe and convenient observation even at high temperatures. (ON3-W)
-
Malfunction prevented by controller lock function.
-
Self-diagnostics function to check abnormal condition of temperature sensor.
※ The lowest temperature that can be controlled depends on changes in room temperature and sample temperature. Therefore, please contact the distributor of our products before purchasing for technical consultation.
※ Technical data (according to DIN 12880, after 2013)
Model |
Solid Door (without window) |
ON3-03 |
ON3-05 |
ON3-10 |
ON3-15 |
Window door |
ON3-03W |
ON3-05W |
ON3-10W |
ON3-15W |
Chamber volume (L / cu ft) |
30 / 66.1 |
50 / 110.2 |
100 / 220.5 |
163 / 359.4 |
Temperature |
Range (℃ / ℉) |
Amb. +15 to 250
/ Amb. +27 to 482 |
Amb. +15 to 250
/ Amb. +27 to 482 |
Amb. +15 to 250
/ Amb. +27 to 482 |
Amb. +15 to 250
/ Amb. +27 to 482 |
Fluctuation at 100℃ (±℃ / ℉) |
0.3 / 0.54 |
0.3 / 0.54 |
0.3 / 0.54 |
0.5 / 0.9 |
Variation at 100℃ (±℃ / ℉) |
2.7 / 4.86 |
3.7 / 6.66 |
7.5 / 13.5 |
4.1 / 7.38 |
Heating time to 100℃ (min.) |
78 |
67 |
74 |
61 |
Recovery time at 100℃ (min.) |
18 |
34 |
39 |
35 |
Dimension
(W×D×H) |
Interior (W x D x H, mm / inch) |
310 x 380 x 252
/ 12.2 x 15.0 x 9.9 |
367 x 437 x 309
/ 14.4 x 17.2 x 12.2 |
463 x 533 x 405
/ 18.2 x 21.0 x 15.9 |
550 x 546 x 542
/ 21.7 x 21.5 x 21.3 |
Exterior (W x D x H, mm / inch) |
488 x 643 x 503
/ 19.2 x 25.3 x 19.8 |
545 x 699 x 560
/ 21.5 x 27.5 x 22.0 |
641 x 796 x 655
/ 25.2 x 31.3 x 25.8 |
728 x 815 x 793
/ 28.7 x 32.9 x 31.2 |
Net weight (Kg / lbs) |
43 / 94.8 |
53 / 116.84 |
63 / 138.9 |
73 / 16.9 |
Shelves |
Quantity of shelves (standard/max.) |
2 / 2 |
2 / 4 |
2 / 5 |
2 /7 |
Max. Load per shelf (Kg / lbs) |
30 / 66.1 |
30 / 66.1 |
30 / 66.1 |
30 / 66.1 |
Electrical requirements (230V, 50 / 60Hz, A) |
3.3 |
3.6 |
5.7 |
7.3 |
Cat. No. |
Solid Door (without window) |
AAH11165K |
AAH11175K |
AAH11185K |
AAH11195K |
Window door |
AAH11265K |
AAH11275K |
AAH11285K |
AAH11295K |
Electrical requirements (120V, 60Hz, A) |
6 |
6.7 |
10.8 |
14.1 |
Cat. No. |
Solid Door (without window) |
AAH11166U |
AAH11176U |
AAH11186U |
AAH11196U |
Window door |
AAH11266U |
AAH11276U |
AAH11286U |
AAH11296U |
Wire & Perforated shelves
Model |
Wire shelves |
Perforated shelves |
Cat. No. |
Quantity of shelves
(standard/max.) |
Cat. No. |
Quantity of shelves
(max.) |
ON3-03/03W |
FDA9542 |
2 / 3 |
AAA125330 |
3 |
ON3-05/05W |
FDA9543 |
2 / 4 |
AAA125331 |
4 |
ON3-10/10W |
FDA9544 |
2 / 6 |
AAA125332 |
6 |
ON3-15/15W |
FDA9545 |
2 / 7 |
AAA125333 |
7 |
※ Included bracket for each shelf
Model |
Description |
Dimension (W x D x H, mm / inch) |
Cat. No. |
OF3, ON3 |
Mobile monitoring system |
156 x 94 x 34 / 6.1 x 3.7 x 1.3 |
AAAQ1011 |
Double-stacked bracket
Oven / incubtor bracket for double stacked.
Model |
Cat. No. |
OF3/ON3-03, 05 |
AAA125421 |
OF3/ON3-10, 15 |
AAA125422 |